GEFRAN 1200 MANUAL PDF

Gefran Manual Online: Configuration/programming. INF Information display This menu provides information on the status and hardware configuration of. Buy Gefran PID Temperature Controller, 48 x 96 (1/8 DIN)mm, 2 Output for selecting functions, automatic/manual selection plus raise and lower keys. Passive Current Loop interface ( baud) or RS 4 wires SERVICE: In GEFRAN è disponibile un reparto di assistenza tecnica.

Author: Kitilar Doukora
Country: Azerbaijan
Language: English (Spanish)
Genre: Literature
Published (Last): 11 January 2008
Pages: 217
PDF File Size: 9.15 Mb
ePub File Size: 4.70 Mb
ISBN: 199-7-17176-828-6
Downloads: 57120
Price: Free* [*Free Regsitration Required]
Uploader: Dozragore

In addition to the control and alarm outputs, you can also have outputs that repeat the state of the digital or retransmission input by process variable, setpoint, deviation, alarm trip points and values acquired via serial line.

You can select one of the two presettable setpoints, select Manual-Automatic mode, reset the alarm memory, or enable the hold function by means of the digital input. Guide Modbus An additional output 24VDC, 30mA max.

Quick Start Guide KB. It is particularly in combined heat-cool control applications where the advanced algorithms come into play, allowing an extremely narrow band between heating and cooling without causing overlap. The instrument’s entire programming procedure is made easier by grouping the parameters in function blocks CFG for control parameters, Inp for inputs, Out for outputs, etc.

The instrument’s entire programming procedure is made easier by grouping the parameters in function blocks CFG for control parameters, Inp for inputs, Out for outputs, etc. Plastic Blow Moulding Machine The purpose of a temperature control loop is to maintain the process temperature accurately at a determined level.

  DESPROTEGER ARQUIVO PDF

Name Manula eXpress Software Quantity: Documentation – Previous versions. By tuning the three parameters in the PID controller algorithm, the controller can provide control action designed for specific process requirements. In this way, you just have to set the setpoint and the alarm, then launch self-tuning with the specific button.

The functions of each output are freely configurable from the faceplate. For more information click here. The instrument can also select the parameters to be displayed based on its hardware configuration, which automatically hides irrelevant parameters. Universal input configurable from faceplate Obtain perfect control mxnual activating autotuning via button on faceplate, making commissioning very easy: Complete operator interface, protected by Lexan membrane to guarantee manuual IP65 faceplate protection level.

An additional output 24VDC, 30mA max. Gefran Temperature Controller: Catalogue Click here for advanced filter options. The functions of each output are freely configurable from the faceplate. An analog output in voltage or in current is also available. For more information and to get a quote for the components illustrated in this control loop, please follow the links on top of the product images.

gefrna

Configuration/programming – Gefran Instructions For Use Manual [Page 19]

Enhanced software and hardware allow a geftan degree of user configurability. Cencal Memory Map – Clicking on a tag will display a list of all products with that tag applied. All parts in the control loop are essential and need to be selected, installed and set up correctly. Acquisition of the input signal msec. You can select one of the two presettable setpointsselect Manual-Automatic mode, reset the alarm memory, or enable the hold function by means of the digital input.

  BIDAYAH WAN NIHAYAH PDF

The main input for the variable to be controlled is universaland allows connection of a wide variety of signals: With scale settable in limits: Know what the controller is doing: Choose from a wide range of software-selectable inputs, including V and mA.: Accuracy better than 0. The Gefran is a high performance configurable controller, widely used in industry for processes involving transmitters 4…20mA, 0…10V and temperature sensors.

Maximum number of outputs: In addition to manal control and alarm outputs, you can also have outputs that repeat the state of the digital or retransmission input by process variable, setpoint, deviation, alarm trip points and values acquired via serial line.

It is particularly in combined Heat-Cool control applications where the advanced algorithms come into play, allowing an extremely narrow band between heating and cooling without causing overlap. A second auxiliary analog input from current transformer is available.

Gefran 1200 Instructions For Use Manual: Configuration/programming

Complete operator interface, protected by Lexan membrane to manial an IP65 faceplate protection level. LEDs will flash when softstart or autotuning are in progress or when a sensor fault occurs Trigger pre-configured control functions alarm reset, Auto Manual mode… via remote switch. The instrument provides up to 4 outputs: Gefran Solutions for Blow Moulding Machines Controllers, sensors, inverters, automation components Gefran Solutions for Injection Moulding Machines controller, sensors, inverters, automation components Gefran Solutions for Plastics Extrusion Machines controller, sensors, inverters, automation components.