View and Download Fluke A instruction manual online. Voltmeter. A Measuring Instruments pdf manual download. Also for: ac. Fluke A Pdf User Manuals. View online or download Fluke A Instruction Manual. Make: Fluke. Model: A, AC. Dealer: User Equip. File, FLUKE A, AC Share technical documentation including product manuals, getting.

Author: Vogar Tojaran
Country: Austria
Language: English (Spanish)
Genre: Literature
Published (Last): 11 July 2012
Pages: 82
PDF File Size: 2.86 Mb
ePub File Size: 1.37 Mb
ISBN: 672-9-48833-987-9
Downloads: 42758
Price: Free* [*Free Regsitration Required]
Uploader: Zolojinn

The voltage appearing at the wiper of R37 is the output voltage of the Kelvin- Varley divider. Finland Tel Franco M-B. Jumper Wire Location Loosen the front panel control knob set screws and remove all of the knots from the front panel. Before attempting to calibrate your instrument, it 893 recommended that the major portions of the instrument circuitry be checked using the methods described in the preceding Precalibration and Trouble- shooting paragraphs.

This instrument is entirely solid state transistors but it’s still pretty old. Enrique Larrete 12 Madrid 16, Spain Tol.

You have to look hard to see it. You have to look hard to see it.

AC DC Differential Voltmeter 893A

Great care has been taken in the design and con- struction of this instrument to isolate the circuitry from chassis ground to reduce common mode measurement errors caused partly by leakage currents. It’s been a while since I knew much about this meter but, if I recall correctly, it uses a specialized and very stable zener diode as its voltage standard. Locate and replace the defective batteries observing proper polarities of connections. The Model AR is also a portable unit, but is of proper width for instal- lation in a standard electronic equipment rack.

  BIOFILM EXOPOLYSACCHARIDES A STRONG AND STICKY FRAMEWORK PDF

fluje Misadjustment of this control will produce null detector open circuit offsets particularly notieable flluke the. Option Kit A com- prises the recorder output and, when, installed in the instrument, is identified as the option on the rear panel decal. This amount flume subject to change until you make payment.

Refer to paragraphs through for disassembly instructions. Remove ac power to the instrument and fuke the jumpers illustrated in Figure between their respective circuit board connections. The ac converter is an operational amplifier driving a full- wave detector whose overall gain is controlled by the neg- ative feedback network selected with the RANGE switch.

In order to filter out the high voltage output ripple, large electrolytic capacitors were attached across the rectified DC node. Mussachiiscils Uadiii C iirp afAmeris. To operate the instrument as an ac or dc differential voltmeter, pro- ceed as follows: On this mode of operation, the NULL SENS switch selects a suitable re- sistance value from the input divider resistors to deter- mine the meter full-scale sensitivity and also applies the Kelvin- Variey divider output to the common input of the null detector.

You are covered by the eBay Money Back Guarantee if you receive an item that is not as described in the listing. Disconnect the dc differential voltmeter from the Model These tests will only check relative instrument operation and are not intended as instrument performance checks.

AC DC Differential Voltmeter A Equipment Fluke, John, Mfg

Note that the electromechanical nulling meter will tend to average out AC ripple the needle can’t move instantaneously. Minimum monthly payments are required.

  CATALOGO CUCINE SCAVOLINI PDF

So a DC measurement using such a digital voltmeter might well be meaningless. The 84 Hz multivibrator provides chopper and demod- ulator drive voltages at a rate asjmchronous to the power 893x frequency.

You attach your 839a leads to the voltage to be measured, then adjust the scale and bridge voltage knobs to yield a zero on the nulling meter an analog electromechanical meter.

I was told that the two series capacitor voltages had been checked with a voltmeter. For replacement, order Reference Divider Resistor Set, part number Calibration of the instrument shoxild be performed on line power with the top and bottom dust covers removed from tte instrument.

Null Detector Calibration Free Local Pickup See details.

Inside Fluke A | John Honniball | Flickr

C’alll’oiitia SoiiOwit 1J r. The input divider is con- nected across the input terminals of the instrument to provide a constant input impedance of megohms on all raises. The remaining circuitry operates similar to the dc differential mode with the only dif- ference being the absence of the polarity reversal switching.

This selected flue A oaoA sistance value is in series with the remaining ten lOOK ohm parts of the first divider and fluie a constant load resistance of 1. The printed circuit boards are inserted in slide holders and will protrude approximately three inches when the instrument is inverted.

This adjust- ment does not affect instrument calibration.