ASTM D1429 PDF

This standard is issued under the fixed designation D; the number immediately These test methods are under the jurisdiction of ASTM Committee D19 on. Purchase your copy of ASTM D – 13 as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards available. The ASTM D, ASTM D, ASTM D (Test method D), ASTM D, IP , API , ASTM D, and ISO test methods cover the laboratory.

Author: Feshicage Vudorisar
Country: Yemen
Language: English (Spanish)
Genre: History
Published (Last): 6 December 2008
Pages: 366
PDF File Size: 4.16 Mb
ePub File Size: 2.7 Mb
ISBN: 878-1-65375-326-9
Downloads: 55667
Price: Free* [*Free Regsitration Required]
Uploader: Fehn

Register for a trial account. Referenced Documents purchase separately The documents listed below are referenced asttm the subject standard but are not provided as part of the standard. The right to access the electronic files of ASTM Standards is for purposes of viewing for individual use only.

Test Method C—Erlenmeyer Flask.

Add to Cart Add to Cart. If you like to setup a quick demo, let us know at support madcad. In addition the electronic files may not be downloaded or distributed elsewhere over computer networks or otherwise.

Standard Test Methods for Specific Gravity of Water and Brine

No further reproductions authorized. It is the responsibility of the user of asrm standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The electronic file may not be reproduced in any way. Please login to your authorized staff account to use this feature. After temperature equilibrium has been reached, the hydrometer scale is read, and the temperature of the test portion is taken.

Remove This Item Compare. The measuring set-up contains three glass cylinders with lids, a support, and a TLC circulator. A TLC refrigerator circulates a cold flow through the double walls of the cylinders. Go to Wish List. Content only available by subscription.

Print 1 2 3 4 5 page sstarting from page current page. Test Method B is preferred for samples of sea water or brines and is more sensitive than Test Method D which has the same general application. The observed hydrometer reading is corrected for the meniscus effect, the thermal glass expansion effect, alternate calibration temperature effects and then reduced to the reference astmm by means of the volume correction factors or tables as applicable by use of the appropriate adjunct to ASTM D guide for petroleum measurement tables API MPMS Chapter There were no books found for the applied search filters.

  IRON KINGDOMS THE WITCHFIRE TRILOGY COLLECTED EDITION PDF

Standard – Standard Test Methods for Specific Gravity of Water and Brine ASTM D –

You currently cannot view this content. Historical Version s – view previous v1429 of standard. Why should you use a Tamson density by hydrometer set-up?

The PTFE valves ensure fast drainage and cleaning of the tube. No items in cart. For the best experience on our site, be sure to turn on Javascript in your browser. Show 9 15 Search book title Enter keywords for book title search. Enter dd1429 personal account email address to request a password reset: ASTM grants you a license as follows: When used in connection with bulk oil measurements, volume correction errors are minimized by observing the hydrometer reading at a temperature close to that of the bulk oil temperature.

Density is an important quality indicator for automotive, aviation and marine fuels, where aastm affects storage, handling and combustion. Knowing the specific gravity will allow determination of a fluid’s characteristics compared to a standard, usually water, at a specified temperature. Link to Active This link will always route to the current Active version of the standard.

JavaScript seems to be disabled in your browser. Please sign into an account with a subscription to this content, or email for help at support madcad.

Enter your account email address to request a password reset: The apparatus can also be used for testing the specific gravity of water and brine, according to ASTM D, test method D.

  KADAM KATHAKAL IN MALAYALAM PDF

ASTM D1429 – 13

This will allow the user to determine if the test fluid will be heavier or lighter than the standard fluid. Density, relative density, or API gravity is a factor governing the quality and pricing of crude petroleum.

However, this property of petroleum is an uncertain indication of its quality unless correlated with other properties. The values given in parentheses are mathematical conversions to inch-pound units that are provided for asm only and are not considered standard.

D Standard Test Methods for Specific Gravity of Water and Brine, –

Our system offers an interesting price advantage compared to other solutions based on a combination of a thermostatic bath and an external chiller. The rack offers full view on the hydrometer.

Test Method C is intended for samples of water containing mud or sludge. The appropriate hydrometer and thermometer, also at a similar temperature, are lowered into the test portion and allowed to settle. The easy detachable leakage tray prevents that portions of the sample are spilled on the workbench. Our special support eliminates the problem of mounting brackets or portions of a thermostatic bath blocking the view.

Are you sure you want to empty the cart? Please contact our sales team sales tamson. Work Item s – proposed revisions of this standard. Remember me for one month. View as Grid List. Why is the standard test method for density, relative density, or API gravity of crude petroleum and liquid petroleum products by hydrometer method important?

The sample is brought to a specified temperature placed in a constant temperature bath to avoid sstm temperature variation during the test and a test portion is transferred to a hydrometer cylinder that has been brought to approximately the same temperature.