ASME NQA-1 2008 PDF

Buy ASME NQA Quality Assurance Requirements For Nuclear Facility Applications from SAI Global. ASME NQA-1– (Revision of ASME NQA-1–). Quality. Assurance. Requirements for. Nuclear Facility. Applications. AN AMERICAN NATIONAL. American Society of Mechanical Engineers (ASME) NQA (95 addenda) and editions. The requirements of these documents shall be complied with .

Author: Tular Mazujin
Country: Switzerland
Language: English (Spanish)
Genre: Spiritual
Published (Last): 23 September 2015
Pages: 275
PDF File Size: 12.34 Mb
ePub File Size: 8.35 Mb
ISBN: 139-5-83981-112-6
Downloads: 93749
Price: Free* [*Free Regsitration Required]
Uploader: Fehn

NSL has established itself as a proven provider of reliable material testing services. Required tests asmf be controlled under appropriate environmental conditions using the tools and equipment necessary to conduct the test in a manner to fulfill test requirements and acceptance criteria.

Measuring or test equipment consistently found to be out-ofcalibration shall be repaired or replaced. Audit results shall be documented and reported to and reviewed by responsible management. We welcome your nuclear inquiries. Positions and Applications Matrices. This may be accomplished by including a list of the specific requirements or by providing, on-site, a copy of the purchase order and the procurement specifications or drawings, together with a suitable certificate.

PD635 ASME NQA-1-2008/1A-2009 Quality Assurance

Identification markings shall be qna-1 using materials and methods that provide a clear and legible identification and do not degrade the function or service life of the item. The procurement documents shall require the Supplier to incorporate appropriate quality assurance program requirements in subtier procurement documents.

This team shall contain one or more Auditors, one being designated Lead Auditor who organizes and directs the audit. Data Analysis and Evaluation.

NQA-1 Compliance for Nuclear Power Generation

Definitions generic to quality assurance activities are included in Part I, Introduction, sectionTerms and Definitions. To assure consistency with outside activities of a similar nature, the Committee is maintaining liaison with other national and nqa- groups that have a similar interest. ASME accepts responsibility for only those interpretations of this document issued in accordance with the established ASME procedures and policies, which precludes the issuance of interpretations by individuals.

  JANDER BLASIUS PDF

The work activities include but are not limited to managing, planning, siting investigation, design, computer software utilization, procurement, fabrication, manufacturing, installing, inspecting, testing, operating, and decommissioning. No part of this document may asmw reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.

Standards, Conventions, and Other Work Practices. The item shall be flushed at the design velocity or other flow velocity if specified in the asmd until the screen shows no more than slight speckling as specified in the procedure in qualitative or quantitative terms, such as the number of particles per unit surface of the screen and no more than slight rust staining.

The organization upon which this Part, or awme thereof, is invoked shall be responsible for complying with the specified requirements of not only Part I but also Part II.

PD ASME NQA/1A Quality Assurance | EHRO-N Portal

Controlled conditions include the use of appropriate equipment, suitable environmental conditions for accomplishing the activity, 208 assurance that prerequisites for the given activity have been satisfied.

If inspection of processed items is impossible or disadvantageous, indirect control by monitoring of processing methods, equipment, and personnel shall be provided. The plan s shall define the cleaning and inspection operations to be used, the system, the responsibilities of the parties concerned for each operation, and the measures to be employed to preserve the cleanness of cleaned surfaces.

These instructions, procedures, or drawings shall define the following, as applicable: Audit responses shall be evaluated by or for the auditing organization. The requirements for any given item shall incorporate restrictions on particulate contaminants, water-soluble contaminants, and water content as appropriate for the item.

The design input shall be specified to the level of detail necessary to permit the design activities to be carried out in a correct manner and to provide a consistent basis for making design decisions, accomplishing design verification measures, and evaluating design changes.

  COMPLETE REFERENCE PHP STEVEN HOLZNER PDF

Approved changes created subsequent to a baseline shall be added to the baseline.

The extent of application is to be determined by the organization imposing the Standard. Section of Requirement 7, Commercial Grade Items and Services, contains criteria applicable to 10 CFR Part 50 for nuclear power plants but provides sufficient quality criteria for the facilities identified in Part 1, Introduction, sectionApplicability.

Configuration item changes shall be controlled until they are incorporated into the approved product baseline. One definition relates to nuclear power plants licensed pursuant to 10 CFR 50 and the second relates to other facilities, per the applicable 10 CFR Parts. Source verification shall be performed in accordance with para. Status indicators shall also provide for indicating the operating status of systems and components of the nuclear facility, such as by tagging valves and switches, to prevent inadvertent operation.

Examples of nuclear facilities are facilities for power generation, spent fuel storage, waste management, fuel reprocessing, nuclear material processing, fuel fabrication, and other related facilities.

Yanek Subcommittee on Interfaces and Administration W. Software verification methods shall include any one or a combination of design reviews, alternate calculations, and tests performed during computer program development. If during this evaluation or at any other time, it is determined by the responsible organization that the capabilities of an individual are not in accordance with the qualification requirements specified for the job, that person shall be removed from that activity until such time as the required capability has been demonstrated.

Configuration items shall be maintained under configuration management until the software is retired.